name | 2330/01S |
---|---|
Description | MPOLP-85P Broadband Power Meter with PCM |
Optical Interface | MPO-12 Interface pinned. Compatible with 50/125 μm/PC Multimode MPO-12. MTP Adapter with Shutter |
Detector Type | InGaAs |
Wavelength Range | 850 to 1550nm |
Standard wavelength settings | 850nm, 1300nm, 1310nm, 1550nm |
Calibrated wavelengths | Multimode: 850nm, 1300nm Singlemode: 1310nm, 1550nm |
Power measurement range | -50 to +3 dBm |
Max. permitted input level | +3 dBm |
Overall Measurement Uncertainty | Multimode: ± 0.7 dB ± 1 nW Singlemode: ± 0.6 dB ± 1 nW |
Linearity | ±0.15dB |
Measurement units | dB, dBm |
Display | 0.01 dB |
Power Meter Functions | Absolute, relative, pass/fail |
Warm Up Time | 20 minutes |
PCM-Optical Interface | FMAE MPO (many other adapters available) |
PCM-Auto pass/fail | IEC 61300-3-35 and custom limits |
PCM-Live Image | 320 x 240 x 8 bit grey, 10 fps |
PCM-Light Source | Blue LED, 100.000+ hours life |
PCM-Lighting Technique | Coaxial |
PCM-Horizontal FoV | 740/370 µm |
PCM-Vertical FoV | 550/275 µm |